[ Home | Request Catalog | Request Sample | Request Quote | Search | Ask Coilcraft ]

High Frequency Current Transformers


Photo


SPECIFICATIONS

Dimensions    Schematic   

View data sheet in Acrobat PDF format


Part Number Turns Inductance
(mH)
Sensed
current
max (A)

Sensitivity

Terminating
resistor
*
(Ohms)
Vout
(V)
Iin
(A)
CS4050V-01 50 5 10 1 1 50
CS4100V-01 100 20 24 1 1 100
CS4200V-01 200 80 35 1 1 200

*Varying terminating resistance will increase or decrease output voltage/Ampere in conductor.
  Effect is essentially linear over a restricted operating range. Frequency response is
  also affected by varying terminating resistance.


[ Home | Request Catalog | Request Sample | Request Quote | Search | Ask Coilcraft ]

Your comments and suggestions are welcome. Contact webmaster@coilcraft.com
Copyright © 1997, Coilcraft, Inc.
Updated:
August 14, 1999

current transformers high frequency current sensing transformers current sense transformers current transfomers current sense transfomers current sensing transfomers