SCES007B - MARCH 1995 - REVISED APRIL 1996
EPIC is a trademark of Texas Instruments Incorporated.
The 'LV165 parallel-load, 8-bit shift registers are designed for 2.7-V to 5.5-V VCC operation.
When the device is clocked, data is shifted toward the serial
output QH. Parallel-in access to each stage is provided by
eight individual direct data inputs that are enabled by a low level
at the SH/
input. The
'LV165 feature a clock inhibit function and a complemented serial
output Q\H.
Clocking is accomplished by a low-to-high transition of the clock
(CLK) input while SH/
is
held high and clock inhibit (CLK INH) is held low. The functions of
the CLK and CLK INH inputs are interchangeable. Since a low CLK input
and a low-to-high transition of CLK INH accomplishes clocking, CLK
INH should be changed to the high level only while CLK is high.
Parallel loading is inhibited when SH/
is held high. The parallel inputs
to the register are enabled while SH/
is held low independently of the levels of CLK, CLK
INH, or SER.
The SN54LV165 is characterized for operation over the full military temperature range of -55°C to 125°C. The SN74LV165 is characterized for operation from -40°C to 85°C.