Question: Using the EVM, trying to access the BIO pin Answer: Use the "OUT" instruction for writing to the control register. See page 3-7 of the C5x Evaluation Module Technical Ref. |
| Device: TMS320C5x Category: TI Tools Detail: Debugger Tools Detail2: Evaluation Module |
Title: Trying to Access the
BIO Pin Source: Case from the TMS320 Hotline Date: 06/19/97 GenId: 0005290 |