Question: Customer would like to make changes to C50 code remotely, initial boot code can be stored in an EPROM, what would you suggest?

Answer: Suggested using the emulator with emuload to load the code, then he can disconnect the emulator and run


Device: TMS320C5x
Category: Device Information
Detail: Bootloading
Title: Make Changes to C50 Code Remotely