Question: How does he store a value from the accumulator into a
memory location not on data page 0? Ex. He'd like to use the SAMM command to store to
location 1000H. Can it be done directly without using auxiliary registers?
Answer: SACL and
SACH instructions would do the job if DP is setup correctly.
Device: TMS320C5x
Category: Device Information
Detail: Registers
Title: Store a Value from
the Accumulator
Source: Case from the TMS320 Hotline
Date: 06/19/97
GenId: 0005771