Question: Can he use 800h for the SARAM for both program and data mem simultaneously?

Answer: The linker cmd file can define program and data space to be anywhere in memory. If you define them to be in the same Ram block then you stand the chance of having more memory access cycle hits.


Device: TMS320C5x
Category: Related Devices
Detail: Memory Interfaces
Title: More Memory Access Cycle Hits
Source: Case from the TMS320 Hotline
Date: 06/19/97
GenId: 0005650