Question: In successive program fetches does strobe always toggle? Is clocking using strobe and it looks like strobe doesn't. On every address change does strobe toggle?

Answer: Strobe doesn't change on back to back cycles, but RD- does for reads and WE- does for writes.


Device: TMS320C5x
Category: Related Devices
Detail: Memory Interfaces
Title: Address Change - Does Strobe Toggle
Source: Case from the TMS320 Hotline
Date: 06/19/97
GenId: 0055590

© Copyright 1998 Texas Instruments Incorporated. All rights reserved.
Trademarks, Important Notice!